MW50
1/2 HP Residential and Light Commercial Sewage Pumps |
Download
Product Brochure
Download Product Manual |
 |
Features
and Benefits
|
|
Enclosed design for high efficiency pumping.
|
|
|
Eliminates possibility
of jamming between impeller and volute. |
|
|
Passes full 2
solids. |
|
|
Original performance
can be restored if wear occurs by replacing volute seat ring. |
|
|
UL, CSA and SSPMA
listed. |
|
|
Oil-filled motor
for maximum heat dissipation and continuous bearing lubrication. |
|
|
High torque, permanent
split capacitor (PSC) motors; no starting switches or relays to wear out. |
|
|
Field tested, wide
angle, mercury-free piggy- back mechanical float switch provides maximum draw
down. (Automatic models only.) |
|
| TWO VANE IMPELLER
DESIGN PROVIDES MAXIMUM PUMP EFFICIENCY. DURABLE MOTOR WILL DELIVER MANY YEARS
OF RELIABLE SERVICE. |
Product Capabilites
| Capacities To |
135 GPM
|
510 LPM
|
| Shut-Off Head |
27 ft.
|
8.23 m
|
| Max. Spherical
Solids |
2 in.
|
50.8 mm
|
| Liquids Handling |
drain water and domestic sewage
|
| Intermittent Liquid Temp. |
up to 140°F
|
up to 60°C
|
| Motor Electrical Data |
1/2 hp, 1625 rpm
PSC (1 ph) oil-filled
115 volts, 9 amps, 1 ph, 60 Hz
230 volts, 4.5 amps, 1 ph, 60 Hz
|
| Motor Insulation |
Class B (130¾ C)
|
| Acceptable pH Range |
5-9
|
| Specific Gravity |
.9-1.1
|
| Viscosity |
28 - 35 SSU
|
| Discharge, NPT |
2 in.
|
50.8 mm
|
| Simplex Dia. |
24 in.
|
61 mm
|
| Duplex Dia. |
36 in.
|
91.4 mm
|
|
Product Performance Chart

|